Ultra High Temperature Graphitizing Furnace
Usage
Ultra high temperature graphitazing treatment for carbon fiber products, C/C composite material, battery negative electrode material, and PI heat conductive graphite film etc.
Feature
3000℃ ultra high temperature, temperature uniformity is less than 10%.
Temperature measurement accuracy 0.3%, temperature control precision ±1℃
Vacuum limit degree can be set according to technology
Siemens PC computer controlled to provide reliable & safe protection
European imported orifice-plate water flow control system for various momitoring
Optimal heat preservation material to keep the lining thermal layer in longer use life
Ultra storage capacity for whole year working parameter records
Fast heat exchange cooling system which can reduce 1/3 temperature decreasing rate.
Specifications
Model | Charge Area Size (Diameter * Height) mm | Rated Temperature (℃) | Rated Heating Power (KW) | Rated Heating Frequency (Hz) | Limiting Vacuum (Pa) |
THL-100 | 100×150 | 3000 | 60 | 4000 | 6.67×10-1 |
THL-150 | 150×200 | 3000 | 80 | 4000 | 6.67×10-1 |
THL-200 | 200×300 | 3000 | 100 | 4000 | 6.67×10-1 |
THL-250 | 250×400 | 3000 | 160 | 2500 | 6.67×10-1 |
THL-300 | 300×500 | 3000 | 200 | 2500 | 6.67×10-1 |
THL-350 | 350×750 | 3000 | 250 | 2500 | 6.67×10-1 |
THL-400 | 400×850 | 3000 | 300 | 2000 | 6.67×10-1 |
THL-500 | 500×1000 | 3000 | 400 | 1500 | 6.67×10-1 |
THL-700 | 700×1100 | 2850 | 500 | 1500 | 6.67×10-1 |
THL-800 | 800×1500 | 2850 | 700 | 1000 | 6.67×10-1 |
THL-900 | 900×1800 | 2850 | 800 | 1000 | 6.67×10-1 |
THL-1100 | 1100×2000 | 2850 | 1000 | 1000 | 6.67×10-1 |
Service Hotline
0731-22335988